Raw water:   tap water, groundwater, reservoir water, deep well water, seawater, etc.
Electrical conductivity:                      <5μS/cm
Voltage:    380V+N50Hz(can be customized)
Capacity:                                             250L~10000L
Productivity:                                      500L/Hour
Desalination rate:                             >98%
Recovery:                                          60% – 75%
Water output:                                   0.25-10t
Custom Support

Most Efficient Pharmaceutical Water System Kit Manufacturer in China

At NEWater, our motto is to provide a highly efficient solution for pharmaceutical water. Ensuring a constant supply of water meeting strict purification criteria is a vital aspect of pharmaceutical production.

We take great care in ensuring that our pharmaceutical water system kit meets all requirements stringently. Purified water production involves the passage of drinking water to pass the criteria for Total Organic Carbon and optimal conductivity. The Water  For Injection requires an additional level for passing the endotoxin test.

video cover

NEWater Pharmaceutical Water System Kit Parameters:

Model
RO-4000LPH
Remark
Production Capacity
4000Liter per hour
Power Supply
220V/380V 50Hz
Customization
Raw Water Pump
2.2KW 
CNP
Quartz Sand Filter
φ800×2000MM
1set SS304
Activated Carbon Filter
φ800×2000MM
2set SS304
Water softener
φ800×2000MM
1set SS304
Cartridge Filter
20‘’ X 5μm pp filter
7pcs
High-Pressure Pump
4KW
CNP
RO Membrane
8040
4pcs
Membrane Housing
SS304
CIP Cleaning System
Filter &Pump &Tank
Pure Water Supply System
UV&Ozone&Cartridge Filter&Pump

 

 

 

Product Name
50 GPD RO Membrane
75 GPD RO Membrane
100 GPD RO Membrane
Length
298 mm
298 mm
298 mm
Diameter
46 mm
46 mm
48 mm
Weight
0.24 KG
0.252 KG
0.284 KG
Salt Rejection
97.50%
97.50%
95.00%
Filter Precision
0.0001 micro
0.0001 micro
0.0001 micro
Material
Aromatic Polyamide Composite Film Element
Aromatic Polyamide Composite Film Element
Aromatic Polyamide Composite Film Element
Capacity
50 gallon per day
75 gallon per day
75 gallon per day
Certification
NSF,ISO20190221
NSF,ISO20190221
NSF,ISO20190221
Carton Packing
25pcs
25pcs
25pcs
Size of 1 Carton
35cm*35cm*35cm
35cm*35cm*35cm
35cm*35cm*35cm
Weight of 1 Carton
7 KG
7.2 KG
7.5 KG
Product Name
200 GPD RO Membrane
400 GPD RO Membrane
Length
298 mm
298 mm
Diameter
68 mm
73 mm
Weight
0.5 KG
0.52 KG
Salt Rejection
97.00%
97.00%
Filter Precision
0.0001 micro
0.0001 micro
Material
Aromatic Polyamide Composite Film Element
Aromatic Polyamide Composite Film Element
Capacity
200 gallon per day
400 gallon per day
Certification
NSF,ISO20190221
NSF,ISO20190221
Carton Packing
25pcs
25pcs
Size of 1 Carton
37cm*52cm*52cm
37cm*52cm*52cm
Weight of 1 Carton
14.9 KG
15.3 KG
NEWater Pharmaceutical Water System Kit Working Flow :
Raw water→booster pump→quartz sand filter→activated carbon filter→water softener (optional)→security filter—-high
pressure pump→RO system→Uv system→Pure water tank
Pharmaceutical Water System Kit Working flow

RO membrane tech

1. Raw water pump– provide the pressure to quartz sand filter/active carbon filter.

2. Quartz sand filter– get rid of turbidity, suspended matter, organic matter, colloid.

3. Active Carbon filter–Remove the color, free chloride, organic matter, harmful matter.

4. Softener(Optional)–exchange “ions” of calcium and magnesium with the most common and easiest method.

5. Security filter–prevent large particles, bacteria, viruses into RO membrane, accuracy is 5um.

6. High-pressure pump– Provide the high pressure to RO membrane.

7. RO Reverse Osmosis Unit — the main part of the plant. RO membrane’s desalting rate can reach 99%.

8. Storage Tank, Achieve treatment effect.

Water Softener System application

HOT FAQ

Get Professional Water Treatment System Solution

Datas for system

Products Details Display

  • Modular design, compact construction, easy installation, and operation. Sampling points at each stage of the system are in optimal condition for easy maintenance and sampling.
  • Multi-channel diaphragm valves replace multiple individual valves, reducing dead space, facilitating evacuation, and reducing costs.
  • The wastewater discharge pipe is integrated into the frame with fewer pipes and fewer welds. Optimal separation of purified water and wastewater.
  • All process steps are arranged on one skid, including pretreatment, softening, filtration, membrane stage, and final desalination EDI and control cabinet.
  • Compact, standardized, prefabricated system, fully tested and pre-tested before delivery.
Pharmaceutical Water System Kit details
Pharmaceutical Water System Kit details1

Why Choose NEWater

1) Using a highly functional and clearly organized design, the two-stage softener series operates Cable ducts and effluent drains are integrated into the frame. All quality-related sampling is integrated into a central panel for easy sampling.
2) Due to the efficient forward and reverse scrubbing methods used in the production process. Plant recovery exceeds 70% in the basic version. Adding the concentrate treatment stage increases the total recovery to 90%. Reduced influent and effluent volumes result in lower operating costs.
3) Each system is pre-qualified and fully functionally tested at our facility prior to shipment. Process technology meets current US Pharmacopoeia and European Pharmacopoeia requirements.
4) The modular concept ensures easy adjustment to customer specifications to meet increased water demands.

 

NEWater Can Promise You

NEWater water treatment solution provider

Pharmaceutical Water System Kit factory
packaging and shipping

How We Transport Your Pharmaceutical Water System Kits?

shipping and packaging

Send Your Inquiry Now

    NEWater Pharmaceutical Water System Kit

    Pharmaceutical units must have an efficient system designed to store, test, and distribute water following the purification process. The industry requires different grades of water, but the most important among them are Water for Injection (WFI), non-compendial water, and Purified Water (PW). The water supply must strictly meet the specifications outlined in the pharmacopeia. One of the key challenges involved is to maintain optimum water quality in the distribution loop. Also necessary is the delivery of water to the point of use at the requisite flow and temperature. Maintaining water quality implies continuous monitoring to prevent biofilm buildup, rouging, and other impurities. Besides, the pharmaceutical water system kit should comply with sustainability parameters but without compromising its quality.

    Pharmaceutical Water System Kit

    NEWater maintains a comprehensive system covering everything from installation to maintenance of the pharmaceutical water system kit. We take into account everything from the current needs of the manufacturing plant to the anticipated need. We work closely with pharmaceutical plants to understand their exact criteria because even over-designing can lead to additional maintenance costs. Furthermore, the water purification systems are designed only after a thorough analysis of the quality of water supply to the plant.

    Purification methods include the application of reverse osmosis and ozone. The pharmaceutical water system kit by NEWater is designed for consistent data analysis. This helps keep microbial growth and biofilm formation in check. Microbial control is particularly difficult because it is inevitable. The extent of microbes in water depends on many variables such as pH, temperature, stresses, and velocity.

    Pharmaceutical Water System Kit

    Also, as the pharmacopeia prohibits using any ‘added substance’ in water, it is important to employ preventive methods consistent with this criteria. Even if anything is added to the water storage system for biofilm sanitization, there must be a complementary system to take it out later. Techniques used to maintain water quality are limited to distillation, electrode ionization, and reverse osmosis.

    Our pharmaceutical water system kit has ample filtration methods employed at strategic points, such as the front end. Other methods include hot water loops, high-pressure sprayers in the components, and mechanical scrubbers. Membrane filters are used, but these must be changed regularly. This is because microbes accumulated on the filters themselves later become a source of the problem. We are open to receiving all queries. We can develop a custom pharmaceutical water system kit following a careful evaluation of your requirements.  

     